학술논문

Piroxicam voltammetric determination by ultra low cost pencil graphite electrode
Document Type
article
Source
Brazilian Journal of Pharmaceutical Sciences, Vol 56 (2020)
Subject
Electroanalysis
Pencil graphite electrode
Piroxicam
Voltammetry
Pharmacy and materia medica
RS1-441
Language
English
ISSN
2175-9790
Abstract
Piroxicam (PRX) was determined in pharmaceutical capsules with differential pulse voltammetry (DPV) in a three electrode system consisting of a pencil graphite electrode (PGE) as working electrode, a Pt wire and a reference electrode of Ag/AgCl/KCl 3 M. An irreversible oxidation peak was observed in Epa c.a. 0.6 V, which correlates to the oxidation of PRX. The coefficient of linear correlation obtained was 0.9946, with limit of detection of 2.1 µM and limit of quantification of 4.7 µM. PGE assays showed good analytical performance compared to high performance liquid chromatography and spectrophotometry, showing the potential to be further developed and employed in quick and simple analyses.