학술논문

Assessing regional hepatic function changes after hypertrophy induction by radioembolisation: comparison of gadoxetic acid-enhanced MRI and 99mTc-mebrofenin hepatobiliary scintigraphy
Document Type
article
Source
European Radiology Experimental, Vol 8, Iss 1, Pp 1-10 (2024)
Subject
Gadolinium ethoxybenzyl DTPA
Liver
Magnetic resonance imaging
Technetium Tc 99 m mebrofenin
Radioembolisation
Medical physics. Medical radiology. Nuclear medicine
R895-920
Language
English
ISSN
2509-9280
Abstract
Abstract Background To compare Gd-ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and 99mTc-labelled mebrofenin hepatobiliary scintigraphy (HBS) as imaging-based liver function tests after unilateral radioembolisation (RE) in patients with primary or secondary liver malignancies. Methods Twenty-three patients with primary or secondary liver malignancies who underwent Gd-EOB-DTPA-enhanced MRI within a prospective study (REVoluTion) were evaluated. REVoluTion was a prospective open-label, non-randomised, therapy-optimising study of patients undergoing right-sided or sequential RE for contralateral liver hypertrophy at a single centre in Germany. MRI and hepatobiliary scintigraphy were performed before RE (baseline) and 6 weeks after (follow-up). This exploratory subanalysis compared liver enhancement on hepatobiliary phase MRI normalised to the spleen (liver-to-spleen ratio (LSR)) and the muscle (liver-to-muscle ratio (LMR)) with mebrofenin uptake on HBS for the total liver (TL) and separately for the right (RLL) and left liver lobe (LLL). Results Mebrofenin uptake at baseline and follow-up each correlated significantly with LSR and LMR on MRI for TL (≤ 0.013) and RLL (≤ 0.049). Regarding the LLL, mebrofenin uptake correlated significantly with LMR (baseline, p = 0.013; follow-up, p = 0.004), whereas with LSR, a borderline significant correlation was only seen at follow-up (p = 0.051; p = 0.046). Conclusion LSRs and LMR correlate with mebrofenin uptake in HBS. This study indicates that Gd-EOB-DTPA-enhanced MRI and 99mTc-labelled mebrofenin HBS may equally be used to assess an increase in contralateral liver lobe function after right-sided RE. Relevance statement MRI may be a convenient and reliable method for assessing the future liver remnant facilitating treatment planning and monitoring of patients after RE-induced hypertrophy induction. Key points • Both MRI and HBS can assess liver function after RE. • Liver enhancement on MRI correlates with mebrofenin uptake on HBS. • MRI might be a convenient alternative for estimating future liver remnants after hypertrophy induction. Graphical Abstract