학술논문

Emission Uniformity of an Annular Graphite Cathode With a Focusing Electrode in a High Power Vacuum Diode
Document Type
article
Source
IEEE Access, Vol 8, Pp 19026-19032 (2020)
Subject
Emission uniformity
graphite cathode
grooved cathode
low guiding magnetic field
high power microwave generation
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Language
English
ISSN
2169-3536
Abstract
The emission uniformity of an annular knife-edged cathode in a coaxial diode with a focusing electrode and operating in a low macro electric field has been investigated. It was found that the emission uniformity deteriorated as the cathode width increased from 0.5 mm to 2.0 mm. To improve the emission uniformity, a grooved graphite cathode was prepared by a laser micro-etching treatment. Experimental results demonstrated that the emission threshold for the grooved cathode may be reduced and thus the delay in explosive emission can be decreased. Visual inspection of photographs of the cathode plasmas operating under different guiding magnetic fields (GMFs) was used to confirm improvements in emission uniformity. Even under a low GMF of 0.21 T, good emission uniformity was realized.