Abstract
Background An elegant bedside provocation test has been shown to aid the diagnosis of long‐QT syndrome (LQTS) in a retrospective cohort by evaluation of QT intervals and T‐wave morphology changes resulting from the brief tachycardia provoked by standing. We aimed to prospectively determine the potential diagnostic value of the standing test for LQTS. Methods and Results In adults suspected for LQTS who had a standing test, the QT interval was assessed manually and automated. In addition, T‐wave morphology changes were determined. A total of 167 controls and 131 genetically confirmed patients with LQTS were included. A prolonged heart rate–corrected QT interval (QTc) (men ≥430 ms, women ≥450 ms) at baseline before standing yielded a sensitivity of 61% (95% CI, 47–74) in men and 54% (95% CI, 42–66) in women, with a specificity of 90% (95% CI, 80–96) and 89% (95% CI, 81–95), respectively. In both men and women, QTc≥460 ms after standing increased sensitivity (89% [95% CI, 83–94]) but decreased specificity (49% [95% CI, 41–57]). Sensitivity further increased (P