학술논문

Ultrasonic shears and bipolar vessel-sealing system for three-port laparoscopic ovariohysterectomy in dogs
Document Type
article
Source
Arquivo Brasileiro de Medicina Veterinária e Zootecnia, Vol 67, Iss 1, Pp 55-61 (2015)
Subject
laparoscopia
caninos
sistemas de coagulação
castração
cirurgia
Animal culture
SF1-1100
Language
English
Portuguese
ISSN
1678-4162
Abstract
In the current experimental study, two different instruments were compared for prophylactic hemostasis during a 3-port technique of laparoscopic ovariohysterectomy (OVH) in bitches. Moreover, the need for port enlargement for specimen retrieval using 5mm or 10mm trocartes, technical difficulties and complications were assessed. Ultrasonic energy and a vascular sealing system were tested. Duration of surgery, patient weight and diameter of the uterine arteries and veins were compared among the groups. Fifteen dogs randomly divided into three groups (GI, GII, GIII) were submitted to ovariohysterectomy with hemostasis from the use of ultrasonic scalpel or vascular sealing equipment. In GI and GII the LigaSure(tm) impedance-controlled bipolar vessel-sealing device was used, differing in the size of trocartes used between groups, and in GIII Autosonix(tm) was used. Patients' weight, duration of surgery, technical difficulties and complications were compared among the groups. Statistical analysis showed no difference between the data analyzed among the groups. In conclusion, both methods of hemostasis were effective for 3-port total laparoscopic ovariohysterectomy in bitches. However, 5mm trocartes were not adequate for retrieval of the uterus and ovaries without need for enlargement of the port incision.