학술논문

Study of a multi-wire proportional chamber with a cathode strip and delay-line readout
Document Type
Academic Journal
Source
中国物理C(英文版) / CHINESE PHYSICS C. 33(5):364-368
Subject
multi-wire proportional chamber
delay-line readout
cathode strip
position resolutio
Language
Chinese
ISSN
1674-1137
Abstract
The design principle for a multi-wire proportional chamber with a cathode strip and delay-line readout is described. A prototype chamber of a size of 10 cm ~ l0 cm was made together with the readout electronics circuit. A very clean signal with very low background noise was obtained by applying a transformer between the delay-line and the pre-amplifier in order to match the resistance. Along the anode wire direction a position resolution of less than 0.5 mm was achieved with a 55Fe-5.9 keV X ray source. The simple structure, large effective area and high position resolution allow the application of a gas chamber of this kind to many purposes.