학술논문

JWST MIRI flight performance: Detector Effects and Data Reduction Algorithms
Document Type
Working Paper
Source
Publications of the Astronomical Society of the Pacific, Volume 135, Number 1049, 2023
Subject
Astrophysics - Instrumentation and Methods for Astrophysics
Language
Abstract
The detectors in the Mid-Infrared Instrument (MIRI) of the James Webb Space Telescope (JWST) are arsenic-21 doped silicon impurity band conduction (Si:As IBC) devices and are direct descendants of the Spitzer IRAC22 long wavelength arrays (channels 3 and 4). With appropriate data processing, they can provide excellent per-23 formance. In this paper we discuss the various non-ideal behaviors of these detectors that need to be addressed24 to realize their potential. We have developed a set of algorithms toward this goal, building on experience with25 previous similar detector arrays. The MIRI-specific stage 1 pipeline algorithms, of a three stage JWST cali-26 bration pipeline, were developed using pre-flight tests on the flight detectors and flight spares and have been27 refined using flight data. This paper describes these algorithms, which are included in the first stage of the28 JWST Calibration Pipeline for the MIRI instrument.