학술논문

Integration of a high finesse cryogenic build-up cavity with an ion trap
Document Type
Working Paper
Source
Subject
Physics - Atomic Physics
Physics - Instrumentation and Detectors
Physics - Optics
Language
Abstract
We report on the realization of a hemispherical optical cavity with a finesse of F = 13000 sustaining inter-cavity powers of 10 kW, which we operate in a closed-cycle cryostat vacuum system close to 4 Kelvin. This was designed and built with an integrated radio-frequency Paul trap, in order to combine optical and radio-frequency trapping. The cavity provides a power build-up factor of 2250. We describe a number of aspects of the system design and operation, including low-vibration mounting and locking including thermal effects at high powers. Thermal self-locking in the high intracavity power regime was observed to enhance the passive stability below 1 kHz. Observations made over repeated cool-downs over a course of a year show a repeatable shift between the ion trap center and the cavity mode.
Comment: 11 pages, 12 figures