Design of a Compact 4π Ge Spectrometer for the Measurement of Neutron Capture Cross Sections of Minor Actinides
Document Type
Article
Source
Journal of Nuclear Science and Technology; December 2004, Vol. 41 Issue: 12 p1129-1137, 9p
Subject
Language
ISSN
00223131; 18811248
Abstract
A compact 4π Ge spectrometer was designed for the measurement of neutron capture cross sections of minor actinides. It consists of two EUROBALL clusters and four clover detectors with BGO shields surrounding a sample as close as possible so as to absorb a few γ-rays of high energy emitted after the neutron capture reaction with reasonable efficiency. This feature opens up the possibility to discriminate the desired nuclide from other impurities based on the measurement of excitation energy and determine the cross section accurately. Overall performances such as total detection efficiencies for 3 cascade γ-rays as well as monochromatic γ-rays were simulated using Geant4. It turned out we could achieve the peak detection efficiency as large as 0.9% for 3 cascade γ-rays, which is almost an order of magnitude larger than the value of the Gammasphere.