학술논문

Research on Crack Prevention of Premixed Concrete of Pump Station Built in Summer
Document Type
Article
Source
Applied Mechanics and Materials; December 2014, Vol. 716 Issue: 1 p379-382, 4p
Subject
Language
ISSN
16609336; 16627482
Abstract
In the summer of southern cities of China, the duration of high temperature becomes longer which requires stricter temperature control and crack prevention measures for mass concrete in construction. By using finite element method for unsteady temperature field and stress field a simulation is made for a pump station built in summer. The cement hydration velocity of this engineering is so high that makes the temperature control very difficulty. Through result analysis of different cases, some optimized measures which include surface preservation and water cooling are proposed. It has an important significance for concrete structure in the same area.