학술논문

Novacor LVAD bridge to transplantation in peripartum cardiomyopathy.
Document Type
Article
Source
European Journal of Cardio-Thoracic Surgery; February 1997, Vol. 11 Issue: 2 p394-396, 3p
Subject
Language
ISSN
10107940; 1873734X
Abstract
We report the case of a 22-year-old woman suffering from peripartum cardiomyopathy who was successfully bridged to cardiac transplantation with a Novacor left ventricular assist device (LVAD). Her course with the device is presented and emphasis is put on the size mismatch between the patient and the device, a fact with normally precludes the implantation of the Novacor LVAD.