Sparks in MSGC and GEM detectors and a robust alternative
Document Type
Article
Source
Nuclear Instruments and Methods in Physics Research Section A; November 2000, Vol. 454 Issue: 1 p272-275, 4p
Subject
Language
ISSN
01689002
Abstract
Sparks in MSGCs can be induced by strongly ionizing particles that damage the anodes. In MSGCs combined with GEMs, the MSGC gain can be reduced below the sparking threshold. However, occasionally discharges in the GEM can produce large secondary sparks at the MSGC. We discuss the dependence of the spark rate on geometrical and electrical parameters of the detectors. Different gas mixtures are compared. The most efficient way to avoid secondary sparks is to reduce the electric field between GEM and MSGC to below 6.6kV/cm. We present first results from a robust alternative to MSGCs, the groove detector.