Detailed operational building data for six office rooms in Denmark: Occupancy, indoor environment, heating, ventilation, lighting and room control monitoring with sub-hourly temporal resolution.
Document Type
Academic Journal
Author
Melgaard SP; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Johra H; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Nyborg VØ; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Marszal-Pomianowska A; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Jensen RL; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Kantas C; Department of Architecture, Design and Media Technology, Aalborg University, Rendsburggade 14, 9000 Aalborg, Denmark.; Larsen OK; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Hu Y; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Frandsen KM; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Larsen TS; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Svidt K; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Andersen KH; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Leiria D; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Schaffer M; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Frandsen M; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Veit M; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Ussing LF; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Lindhard SM; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Pomianowski MZ; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Rohde L; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Hansen AR; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.; Heiselberg PK; Department of the Built Environment, Aalborg University, Thomas Manns vej 23, 9220 Aalborg Øst, Denmark.
Source
Publisher: Elsevier B.V Country of Publication: Netherlands NLM ID: 101654995 Publication Model: eCollection Cited Medium: Internet ISSN: 2352-3409 (Electronic) Linking ISSN: 23523409 NLM ISO Abbreviation: Data Brief Subsets: PubMed not MEDLINE
Subject
Language
English
Abstract
The operational building data presented in this paper has been collected from six office rooms located in an office building (research and educational purposes) located on the main campus of Aalborg University in Denmark. The dataset consists of measurements of occupancy, indoor environmental quality, room-level and system-level heating, ventilation and lighting operation at a 5 min resolution. The indoor environmental quality and building system data were collected from the building management system. The occupancy level in each monitored room is established from the computer vision-based analysis of wall-mounted camera footage of each office. The number of people present in the room is estimated using the YOLOv5s image recognition algorithm. The present dataset can be used for occupancy analysis, indoor environmental quality investigations, machine learning, and model predictive control.
(© 2024 The Author(s).)