학술논문

High incidence of intraoperative calcar fractures with the cementless CLS Spotorno stem.
Document Type
Academic Journal
Author
Timmer C; Department of Orthopedics, Rijnstate Hospital, P.O. Box 9555, 6800 TA, Arnhem, The Netherlands.; Gerhardt DMJM; Department of Orthopedics, Rijnstate Hospital, P.O. Box 9555, 6800 TA, Arnhem, The Netherlands.; de Visser E; Department of Orthopedics, Rijnstate Hospital, P.O. Box 9555, 6800 TA, Arnhem, The Netherlands.; de Kleuver M; Department of Orthopedics, Radboud University, Nijmegen, The Netherlands.; van Susante JLC; Department of Orthopedics, Rijnstate Hospital, P.O. Box 9555, 6800 TA, Arnhem, The Netherlands. jvansusante@rijnstate.nl.
Source
Publisher: Springer-Verlag France Country of Publication: France NLM ID: 9518037 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1432-1068 (Electronic) Linking ISSN: 16338065 NLM ISO Abbreviation: Eur J Orthop Surg Traumatol Subsets: MEDLINE
Subject
Language
English
Abstract
Introduction: This study reports on the incidence of intraoperative calcar fractures with the cementless Spotorno (CLS) stem, and the potential role of a learning curve and implant positioning is investigated.
Methods: After introduction of the CLS stem, 800 consecutive cementless total hip arthroplasties (THA) were analyzed. The incidence of calcar fracture in the first 400 THA was compared with the second 400 THA, in order to study a potential learning curve effect. According to the instruction for users, varus positioning of the stem was avoided and a femoral neck osteotomy was aimed relatively close to the lesser trochanter since these are assumed to be correlated with calcar fractures. Implant positioning (neck-shaft angle, femoral offset and osteotomy-lesser trochanter distance) was measured on postoperative pelvic radiographs of all THA with calcar fractures and 100 randomly selected uncomplicated control cases.
Results: Seventeen (2.1%) intraoperative calcar fractures were recorded. The incidence of calcar fracture differed between the first 400 THA (n = 11) and the second 400 THA (n = 6). This difference was not statistically significant (p = 0.220); however, these numbers indicate a trend toward a learning effect. No significant difference in stem positioning nor the height of the femoral neck osteotomy was measured between THA with a calcar fracture (n = 17) and the control cases (n = 100).
Conclusions: We report on a high incidence of intraoperative calcar fractures with the use of a CLS stem. The risk for calcar fractures remains clinically significant even after adequate implant positioning in the hands of experienced hip surgeons. Surgeons should be aware of this implant related phenomenon and be alert on this phenomenon intraoperatively.