학술논문

Portable NIV for patients with moderate to severe COPD: two randomized crossover trials.
Document Type
Journal Article
Source
Respiratory Research. 4/26/2021, Vol. 22 Issue 1, p1-12. 12p.
Subject
*CROSSOVER trials
*INTERMITTENT claudication
*OBSTRUCTIVE lung diseases
*PATIENT selection
*NONINVASIVE ventilation
*TREATMENT programs
*ARTIFICIAL respiration equipment
*OBSTRUCTIVE lung disease diagnosis
*TREATMENT of dyspnea
*DIAGNOSIS of dyspnea
*OBSTRUCTIVE lung disease treatment
*RESEARCH
*EXERCISE tolerance
*LUNGS
*MECHANICAL ventilators
*CONVALESCENCE
*TIME
*RESEARCH methodology
*MEDICAL cooperation
*EVALUATION research
*DYSPNEA
*ARTIFICIAL respiration
*TREATMENT effectiveness
*PRODUCT design
*SEVERITY of illness index
*COMPARATIVE studies
*RANDOMIZED controlled trials
*WALKING
*FORCED expiratory volume
Language
ISSN
1465-9921
Abstract
Background: Long-term non-invasive ventilation (NIV) is as an established treatment option for chronic hypercapnic COPD patients. Beneficial effects have also been shown during exercise, but this is restricted to rehabilitation programs. New portable NIV (pNIV) devices may now enable NIV application during walking at home.Study Design and Methods: In two randomized crossover trials, the impact of pNIV on dyspnea and endurance capacity was investigated in patients with moderate to severe COPD. Participants performed a standardized 6-min walking test, with and without pNIV, using a pre-set inspiratory/expiratory positive airway pressure of 18/8 cmH2O. The first study was performed in NIV-naïve patients (Study I), while the second study was performed in those already established on long-term NIV (Study II).Results: 38 patients (66.9 ± 7.4 years, mean FEV1: 30.3 ± 8%pred) and 23 patients (67.6 ± 8.7 years, mean FEV1: 29.8 ± 10.4%pred) participated in Study I and II, respectively. In Study I, the mean difference in the Borg Dyspnea Scale (BDS, primary outcome) score following walking was 3.2 (IQR 2-4) without pNIV, compared to 2.6 (IQR 1-4) with pNIV (ΔBDS 0.65, P = 0.04), while walking distance increased from 311.8 m (95%CI 276.9-346.6 m) to 326.3 m (95%CI 291.5-361.2 m) (P = 0.044) when pNIV was used. Accordingly, in Study II, the mean difference in BDS was 4.4 (IQR 3-6) without pNIV, compared to 4.5 (IQR 3-6) with pNIV (ΔBDS 0.09, P = 0.54), while walking distance decreased from 291.5 m (95%CI 246.1-336.9 m) to 258.4 m (95%CI 213-303.8 m) (P ≤ 0.001).Interpretation: The use of a pNIV device during walking can improve dyspnea and walking distance in patients with moderate to severe COPD. Patients who do not already receive long-term NIV therapy are more likely to benefit compared to those undergoing long-term NIV. Careful patient selection is mandatory. Clinical Trial Register: DRKS00013203; DRKS00012913 registered October 20th 2017 and October 16th 2017; https://www.drks.de/drks_web/. [ABSTRACT FROM AUTHOR]