학술논문

Manufacturing and High Heat Flux Testing of Tungsten-Brazed Mock-Ups for KSTAR Divertor.
Document Type
Article
Source
IEEE Transactions on Plasma Science. Mar2017, Vol. 45 Issue 3, p519-522. 4p.
Subject
*FUSION reactor divertors
*TUNGSTEN
*BRAZING
*HEAT flux
*PLASMA temperature
*SURFACE roughness
Language
ISSN
0093-3813
Abstract
Development of tungsten brazing technology for the upgraded Korea superconducting tokamak advanced research divertor was launched in early 2013. ITER grade tungsten block was brazed on the CuCrZr alloy in vacuum at 980 °C for 30 min using silver free brazing alloy. An OFHC-copper was used as an interlayer between tungsten and the CuCuZr. The brazing alloy is a 0.05 mm thickness of plate of which component is a Ni–Cu–Mn. It is found that the optimal loading on mock-up is about 20 kPa. Ultrasonic test and shear strength test were carried out to check the strength between tungsten and substrate material. And the joint conditions were analyzed by scanning electron microscopy. Tungsten-brazed mock-ups with a cooling tube were tested at the electron beam facility, Korea heat load test facility-electron beam in Korea Atomic Energy Research Institute. The high heat flux test was performed for tungsten-brazed mock-ups under heat flux of about 5 MW/ \textm^2 with more than 2000 cycles. All the tungsten-brazed mock-ups met the requirements and there was no delamination or failure at the bonding joints. [ABSTRACT FROM PUBLISHER]