학술논문

Translating preventive chemotherapy prevalence thresholds for Schistosoma mansoni from the Kato-Katz technique into the point-of-care circulating cathodic antigen diagnostic test.
Document Type
Article
Source
PLoS Neglected Tropical Diseases. 12/14/2018, Vol. 12 Issue 12, p1-21. 21p.
Subject
*SCHISTOSOMA mansoni
*POINT-of-care testing
*CANCER chemotherapy
*SCHISTOSOMA
*ROUTINE diagnostic tests
Language
ISSN
1935-2727
Abstract
Background: Intervention guidelines against Schistosoma mansoni are based on the Kato-Katz technique. However, Kato-Katz thick smears show low sensitivity, especially for light-intensity infections. The point-of-care circulating cathodic antigen (POC-CCA) is a promising rapid diagnostic test detecting antigen output of living worms in urine and results are reported as trace, 1+, 2+, and 3+. The use of POC-CCA for schistosomiasis mapping, control, and surveillance requires translation of the Kato-Katz prevalence thresholds into POC-CCA relative treatment cut-offs. Furthermore, the infection status of egg-negative but antigen-positive individuals and the intensity-dependent sensitivity of POC-CCA should be estimated to determine its suitability for verification of disease elimination efforts. Methodology: We used data from settings in Africa and the Americas characterized by a wide range of S. mansoni endemicity. We estimated infection intensity-dependent sensitivity and specificity of each test at the unit of the individual, using a hierarchical Bayesian egg-count model that removes the need to define a ‘gold’ standard applied to data with multiple Kato-Katz thick smears and POC-CCA urine cassette tests. A simulation study was carried out based on the model estimates to assess the relation of the two diagnostic tests for different endemicity scenarios. Principal findings: POC-CCA showed high specificity (> 95%), and high sensitivity (> 95%) for moderate and heavy infection intensities, and moderate sensitivity (> 75%) for light infection intensities, and even for egg-negative but antigen-positive infections. A 10% duplicate slide Kato-Katz thick smear prevalence corresponded to a 15–40% prevalence of ≥ trace-positive POC-CCA, and 10–20% prevalence of ≥ 1+ POC-CCA. The prevalence of ≥ 2+ POC-CCA corresponded directly to single slide Kato-Katz prevalence for all prevalence levels. Conclusions/significance: The moderate sensitivity of POC-CCA, even for very light S. mansoni infections where the sensitivity of Kato-Katz is very low, and the identified relationship between Kato-Katz and POC-CCA prevalence thresholds render the latter diagnostic tool useful for surveillance and initial estimation of elimination of S. mansoni. For prevalence below 10% based on a duplicate slide Kato-Katz thick smear, we suggest using POC-CCA including trace results to evaluate treatment needs and propose new intervention thresholds that need to be validated in different settings. [ABSTRACT FROM AUTHOR]