학술논문

A comparison of simplified protocols of personalized dosimetry in NEN patients treated by radioligand therapy (RLT) with [177Lu]Lu-DOTATATE to favor its use in clinical practice.
Document Type
Article
Source
European Journal of Nuclear Medicine & Molecular Imaging. May2023, Vol. 50 Issue 6, p1753-1764. 12p. 8 Charts, 3 Graphs.
Subject
*ABSORBED dose
*NEUROENDOCRINE tumors
*BONE marrow
*SPLEEN
*LUTETIUM compounds
Language
ISSN
1619-7070
Abstract
The role of internal dosimetry is usually proposed for investigational purposes in patients treated by RLT, even if its application is not yet the standard method in clinical practice. This limited use is partially justified by several concomitant factors that make calculations a complex process. Therefore, simplified dosimetry protocols are required. Methods: In our study, dosimetric evaluations were performed in thirty patients with NENs who underwent RLT with [177Lu]Lu-DOTATATE. The reference method (M0) calculated the cumulative absorbed dose performing dosimetry after each of the four cycles. Obtained data were employed to assess the feasibility of simplified protocols: defining the dosimetry only after the first cycle (M1) and after the first and last one (M2). Results: The mean differences of the cumulative absorbed doses between M1 and M0 were – 10% for kidney, – 5% for spleen, + 34% for liver, + 13% for red marrow, and + 37% for tumor lesions. Conversely, differences lower than ± 10% were measured between M2 and M0. Conclusion: Cumulative absorbed doses obtained with the M2 protocol resembled the doses calculated by M0, while the M1 protocol overestimated the absorbed doses in all organs at risk, except for the spleen. [ABSTRACT FROM AUTHOR]