학술논문

Assessment of quadricuspid aortic valve with real time three-dimensional transthoracic echocardiography.
Document Type
Article
Source
Cardiologia Croatica. May/Jun2013, Vol. 8 Issue 5/6, p171-172. 2p.
Subject
*AORTIC valve diseases
*HEART valve diseases
*CARDIAC contraction
*TRANSESOPHAGEAL echocardiography
HEART disease research
Language
ISSN
1848-543X
Abstract
Background: A quadricuspid aortic valve (QAV) is a rare congenital valvular malformation with common need for surgical intervention. Real time three-dimensional transthoracic echocardiography (3D TTE) may be helpful in assessment this abnormality, since complex spatial geometry, dynamic changes, and regurgitation quantification of the valve can be accurately determined . Case report: A 23-year-old female presented with dispnea on exertion and palpitations. Transthoracic echocardiography (TTE) revealed normal systolic function and an unusual aortic valve with fibrous thickening of cusps edges (Figure 1A) and moderate aortic regurgitation (AR) (Figure 1B). Transesophageal echocardiography (TEE) noted a QAV with two equal large cusps and two equal smaller cusps. In addition, 3D TTE was performed. After slight tilting and adjustment of the cropping plane in the high parasternal short axis view, four cusps were clearly visualized in diastole (Figure 2A) and systole (Figure 2B). 3D color Doppler demonstrated mild aortic regurgitation (AR) with slightly eccentric jet. Low regurgitant volume of AR was further confirmed with magnetic resonance imaging (MRI). Surgical intervention was not indicated. Discussion: Serial echocardiographic evaluations of AR seem to be an optimal diagnostic method to determine the potential need for surgical intervention. The effective regurgitant orifice area may be the most hemodynamically important parameter for quantification of AR severity, but it is difficult to derive in many cases of QAV with frequently eccentric jet. 2D TTE assessment of QAV which relies on the relationship between the size of the jet and regurgitant volume could be unreliable . TEE is semi-invasive and not without risk. MRI derives accurate measurements, but the method is not eligible for regular follow-up. As the 3D TTE color Doppler measurements of regurgitation flow can be done in three dimensions, assessment of QAV could be more reliable in comparison to conventional echocardiography . Conclusion: 3D echocardiography has the potential to become the standard examination procedure for the assessment of QAV. [ABSTRACT FROM AUTHOR]