학술논문

Fluctuations in intra-ocular pressure with sleep: I. Time course of IOP increase after the onset of sleep.
Document Type
Article
Source
Ophthalmic & Physiological Optics. Jul88, Vol. 8 Issue 3, p246-248. 3p.
Subject
*INTRAOCULAR pressure
*SLEEP
*GLAUCOMA
*TONOMETERS
*EYE
*PATIENTS
Language
ISSN
0275-5408
Abstract
Ten normal subjects slept over a series of four nights for time periods of 30 minutes, 1, 2 and 4 hours. Intra-ocular pressure (IOP) measurements were made using a non-contact tonometer before and after sleep. The subjects showed a significant increase in IOP of 3.45 mm Hg after 30 minutes of sleep and a further IOP increase thereafter to 6.41 mm Hg above baseline. Such increases in IOP after sleep in normal subjects suggest that glaucoma patients and those suspected of having glaucoma should be monitored overnight to assess their IOP control mechanisms. [ABSTRACT FROM AUTHOR]