학술논문

Development and Investigation of a Two-Phase Loop Thermosiphon with a Flat Evaporator at Different Slope Angles.
Document Type
Article
Source
High Temperature. Jan2018, Vol. 56 Issue 1, p92-97. 6p.
Subject
*TWO-phase flow
*THERMOSIPHON effect
*EVAPORATORS
*WORKING fluids
*GEOMETRIC surfaces
*THERMAL resistance
Language
ISSN
0018-151X
Abstract
We present the results of the development and experimental studies of a two-phase loop thermosiphon with a flat evaporator and ethanol as the working fluid. We investigate the thermal characteristics of the device within the temperature range of 20-80°C under the heat loads of 10-120 W, a filling ratio of 40%, and slope angles within the range of 0°-90°. The device is functional at all of the studied slope angles. The maximum heat load of 120 W was reached at the slope angle of 90°. Here, the average temperature of the evaporator surface was within 70°C and the maximum thermal resistance was equal to 0.41°C/W. [ABSTRACT FROM AUTHOR]