학술논문

Near infra-red fluorescence identification of the thoracic duct to prevent chyle leaks during oesophagectomy.
Document Type
Article
Source
Surgical Endoscopy & Other Interventional Techniques. Jul2022, Vol. 36 Issue 7, p5319-5325. 7p.
Subject
Language
ISSN
1866-6817
Abstract
Background: Chyle leaks following oesophagectomy are a frustrating complication of surgery with considerable morbidity. The use of near infra-red (NIR) fluorescence in surgery is an emerging technology and the use of fluorescence to identify the thoracic duct has been demonstrated in animal work and early human case reports. This study evaluated the use mesenteric and enteral administration of indocyanine green (ICG) in humans to identify the thoracic duct during oesophagectomy. Methods: Patients undergoing oesophagectomy were recruited to the study. Administration of ICG via an enteral route or mesenteric injection was evaluated. Fluorescence was assessed using a NIR fluorescence enabled laparoscope system with a visual scoring system and signal to background ratios. Visualisation of the thoracic duct under white light and NIR fluorescence was compared as well as any identification of active chyle leak. Patients were followed up post-operatively for adverse events and chyle leak. Results: 20 patients received ICG and were included in the study. The enteral route failed to fluoresce the thoracic duct. Mesenteric injection (17 patients) identified the thoracic duct under fluorescence prior to white light in 70% of patients with a mean signal to background ratio of 5.35. In 6 participants, a possible active chyle leak was identified under fluorescence with 4 showing active chyle leak from what was identified as the thoracic duct. Conclusion: This study demonstrates that ICG administration via mesenteric injection can highlight the thoracic duct during oesophagectomy and may be a potential technology to reduce chyle leak following surgery. Clinical trial registration: Clinical trials.gov (NCT03292757). [ABSTRACT FROM AUTHOR]

Online Access