학술논문

Efficacy of a Standalone Microporous Ceramic Versus Autograft in Instrumented Posterolateral Spinal Fusion: A Multicenter, Randomized, Intrapatient Controlled, Noninferiority Trial.
Document Type
Journal Article
Source
Spine (03622436). 7/15/2020, Vol. 45 Issue 14, p944-951. 8p.
Subject
*BONE substitutes
*AUTOTRANSPLANTATION
*BONE grafting
*CERAMICS
*COMPUTED tomography
*SPINAL fusion
Language
ISSN
0362-2436
Abstract
Study Design: in the rest of the article written as patient- and observer-blinded, multicenter, randomized, intrapatient controlled, noninferiority trial.Objective: The aim of this study was to determine noninferiority of a biphasic calcium-phosphate (AttraX® Putty) as a bone graft substitute for autograft in instrumented posterolateral fusion (PLF).Summary Of Background Data: Spinal fusion with autologous bone graft is a frequently performed surgical treatment. Several drawbacks of autografting have driven the development of numerous alternatives including synthetic ceramics. However, clinical evidence for the standalone use of these materials is limited.Methods: This study included 100 nontraumatic adults who underwent a primary, single- or multilevel, thoracolumbar, instrumented PLF. After instrumentation and preparation for grafting, the randomized allocation side of AttraX® Putty was disclosed. Autograft was applied to the contralateral side of the fusion trajectory, so each patient served as his/her own control. For the primary efficacy outcome, PLF was assessed at 1-year follow-up on computed tomography scans. Each segment and side was scored as fused, doubtful fusion, or nonunion. After correction for multilevel fusions, resulting in a single score per side, the fusion performance of AttraX Putty was tested with a noninferiority margin of 15% using a 90% confidence interval (CI).Results: There were 49 males and 51 females with a mean age of 55.4 ± 12.0 (range 27-79) years. Two-third of the patients underwent a single-level fusion and 62% an additional interbody fusion procedure. The primary analysis was based on 87 patients, including 146 instrumented segments. The fusion rate of AttraX Putty was 55% versus 52% at the autograft side, with an overall fusion rate of 71%. The 90% CI around the difference in fusion performance excluded the noninferiority margin (difference = 2.3%, 90% CI = -9.1% to +13.7%).Conclusion: The results of this noninferiority trial support the use of AttraX Putty as a standalone bone graft substitute for autograft in instrumented thoracolumbar PLF.Level Of Evidence: 1. [ABSTRACT FROM AUTHOR]