학술논문

Individual response in patient's effort and driving pressure to variations in assistance during pressure support ventilation.
Document Type
Article
Source
Annals of Intensive Care. 12/20/2023, Vol. 13 Issue 1, p1-9. 9p.
Subject
*RESPIRATORY muscle physiology
*RESPIRATORY muscles
*PRESSURE breathing
*RESPIRATORY insufficiency
*CONFIDENCE intervals
*RESPIRATORY measurements
*ARTIFICIAL respiration
*BODY surface area
*PEARSON correlation (Statistics)
*RANDOMIZED controlled trials
*DESCRIPTIVE statistics
*RESEARCH funding
*RESPIRATION
*ELECTROMYOGRAPHY
*STATISTICAL sampling
*BODY mass index
*RESPIRATORY mechanics
Language
ISSN
2110-5820
Abstract
Background: During Pressure Support Ventilation (PSV) an inspiratory hold allows to measure plateau pressure (Pplat), driving pressure (∆P), respiratory system compliance (Crs) and pressure-muscle-index (PMI), an index of inspiratory effort. This study aims [1] to assess systematically how patient's effort (estimated with PMI), ∆P and tidal volume (Vt) change in response to variations in PSV and [2] to confirm the robustness of Crs measurement during PSV. Methods: 18 patients recovering from acute respiratory failure and ventilated by PSV were cross-randomized to four steps of assistance above (+ 3 and + 6 cmH2O) and below (-3 and -6 cmH2O) clinically set PS. Inspiratory and expiratory holds were performed to measure Pplat, PMI, ∆P, Vt, Crs, P0.1 and occluded inspiratory airway pressure (Pocc). Electromyography of respiratory muscles was monitored noninvasively from body surface (sEMG). Results: As PSV was decreased, Pplat (from 20.5 ± 3.3 cmH2O to 16.7 ± 2.9, P < 0.001) and ∆P (from 12.5 ± 2.3 to 8.6 ± 2.3 cmH2O, P < 0.001) decreased much less than peak airway pressure did (from 21.7 ± 3.8 to 9.7 ± 3.8 cmH2O, P < 0.001), given the progressive increase of patient's effort (PMI from -1.2 ± 2.3 to 6.4 ± 3.2 cmH2O) in line with sEMG of the diaphragm (r = 0.614; P < 0.001). As ∆P increased linearly with Vt, Crs did not change through steps (P = 0.119). Conclusion: Patients react to a decrease in PSV by increasing inspiratory effort—as estimated by PMI—keeping Vt and ∆P on a desired value, therefore, limiting the clinician's ability to modulate them. PMI appears a valuable index to assess the point of ventilatory overassistance when patients lose control over Vt like in a pressure-control mode. The measurement of Crs in PSV is constant—likely suggesting reliability—independently from the level of assistance and patient's effort. [ABSTRACT FROM AUTHOR]