학술논문

Two‐year outcomes of the ARTISAN‐SNM study for the treatment of urinary urgency incontinence using the Axonics rechargeable sacral neuromodulation system
Document Type
article
Source
Neurourology and Urodynamics. 40(2)
Subject
Biomedical and Clinical Sciences
Clinical Sciences
Clinical Research
Clinical Trials and Supportive Activities
Electric Stimulation Therapy
Female
Follow-Up Studies
Humans
Male
Quality of Life
Sacrum
Time Factors
Treatment Outcome
Urinary Incontinence
Urge
clinical trial
implantable neurostimulator
overactive bladder
sacral neuromodulation
urinary urgency incontinence
Neurosciences
Urology & Nephrology
Clinical sciences
Language
Abstract
AimsSacral neuromodulation (SNM) is a guideline-recommended treatment with proven therapeutic benefit for urinary urgency incontinence (UUI) patients. The Axonics® System is the first Food and Drug Administration-approved rechargeable SNM system and is designed to deliver therapy for a minimum of 15 years. The ARTISAN-SNM study was designed to evaluate UUI participants treated with the Axonics System. Two-year follow-up results are presented.MethodsOne hundred and twenty-nine UUI participants underwent implantation with the Axonics System. Therapeutic response rate, participant quality of life (QoL), and satisfaction were determined using 3-day voiding diaries, ICIQ-OABqol, and satisfaction questionnaires. Participants were considered responders if they had a 50% or greater reduction in UUI episodes post-treatment. As-treated and Completers analyses are presented.ResultsAt 2 years, 93% of the participants (n = 121 Completers at 2 years) were therapy responders, of which 82% achieved ≥ 75% reduction in UUI episodes and 37% were dry (100% reduction). Daily UUI episodes reduced from 5.6 ± 0.3 at baseline to 1.0 ± 0.2 at 2 years. Statistically significant improvements in ICIQ-OABqol were reported. All participants were able to recharge their device and 94% of participants reported that the recharging frequency and duration were acceptable. Participant demographics nor condition severity were correlated with clinical outcomes or recharging experience. No unanticipated or serious device-related adverse events occurred.ConclusionsAt 2 years, participants treated with the Axonics System demonstrated sustained safety and efficacy, high levels of satisfaction with therapy and recharging. Participant-related factors were not associated with efficacy or recharging outcomes, indicating the reported results are applicable to a diverse population.