학술논문

Cone photoreceptor macular function and recovery after photostress in early non-exudative age-related macular degeneration
Document Type
Academic Journal
Source
Clinical Ophthalmology. Annual, 2018, Vol. 12, p1325, 11 p.
Subject
Diabetic retinopathy -- Physiological aspects
Macular degeneration -- Physiological aspects
Language
English
ISSN
1177-5483
Abstract
Purpose: To identify parameters from cone function and recovery after photostress that detect functional deficits in early non-exudative age-related macular degeneration (AMD) and to determine the repeatability of these parameters. Methods: Cone-mediated visual function recovery after photostress was examined in three groups of subjects: young normal subjects (ages 20-29; N=8), older normal subjects (ages 50-90; N=9), and early non-exudative AMD subjects (ages 50-90; N=12). Eight AMD and four normal subjects were retested 1 year after the initial evaluation. Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity (VA) and parameters of cone function (baseline cone sensitivity and cone recovery half-life following photobleach) were measured and compared between AMD and normal subjects. Short-term repeatability was assessed for each subject's initial evaluation. Long-term repeatability was assessed by comparing outcomes from the initial evaluation and 1-year follow-up. Results: The mean baseline cone threshold was significantly worse in subjects with early AMD compared to older normal subjects (-1.80[+ or -]0.04 vs-1.57[+ or -]0.06 log cd/[m.sup.2] p=0.0027). Moreover, the baseline cone threshold parameter exhibited good short-term (intraclass correlation coefficient [ICC]=0.88) and long-term (ICC=0.85) repeatability in all subjects. The cone intercept parameter and ETDRS VA were not significantly different between AMD and older normal subject groups. Cone recovery half-life was significantly different between older normal and AMD subject groups (p=0.041). Neither ETDRS VA nor cone function parameters were significantly different for any group at the 1-year follow-up. Conclusion: The baseline cone threshold shows potential as a novel parameter to assess visual dysfunction in early AMD. This outcome consistently detected deficits in AMD subjects, and differentiated them from age-matched controls with high test-retest repeatability. Keywords: AMD, photobleach, photoreceptor, cone recovery, Ora LUX
Introduction In the developed world, age-related macular degeneration (AMD) is the leading cause of blindness in individuals 50 years and older. (1) As the life-expectancy increases, the prevalence of AMD [...]