학술논문

Generation of High Brightness X-rays with the PLEIADES Thomson X-ray Source
Document Type
Conference
Author
Source
Conference: 2003 Particle Accelerator Conference, Portland, OR, May 12 - May 16, 2003
Subject
70 ACCELERATORS
BRIGHTNESS
ELECTRON BEAMS
ELECTRONS
EVALUATION
LASERS
LAWRENCE LIVERMORE NATIONAL LABORATORY
PRODUCTION
SIMULATION
TAIL ELECTRONS
THOMSON SCATTERING
TRANSPORT
X-RAY SOURCES
Language
English
Abstract
The use of short laser pulses to generate high peak intensity, ultra-short x-ray pulses enables exciting new experimental capabilities, such as femtosecond pump-probe experiments used to temporally resolve material structural dynamics on atomic time scales. PLEIADES (Picosecond Laser Electron InterAction for Dynamic Evaluation of Structures) is a next generation Thomson scattering x-ray source being developed at Lawrence Livermore National Laboratory (LLNL). Ultra-fast picosecond x-rays (10-200 keV) are generated by colliding an energetic electron beam (20-100 MeV) with a high intensity, sub-ps, 800 nm laser pulse. The peak brightness of the source is expected to exceed 10{sup 20} photons/s/0.1% bandwidth/mm2/mrad2. Simulations of the electron beam production, transport, and final focus are presented. Electron beam measurements, including emittance and final focus spot size are also presented and compared to simulation results. Measurements of x-ray production are also reported and compared to theoretical calculations.