학술논문
Performance of the Front-End Electronics of the PADME charged particle detector system
Document Type
Conference
Author
Source
2018 IEEE XXVII International Scientific Conference Electronics - ET Scientific Conference Electronics - ET, 2018 IEEE XXVII International. :1-4 Sep, 2018
Subject
Language
Abstract
The PADME charged particle detector system should detect positrons and electrons with efficiency better than 99 {\%} and time resolution below 1 ns. The system hosts about 200 readout electronics channels whose operation has to be verified and commissioned. A custom based test system allowing to perform qualitative check of the produced frontend electronics has been developed and was used to test a total of 256 channels. The obtained time resolution was found to be consistent with the requirements and better than 500 ps for all the channels.