학술논문

Real-life experience with a new anticoagulation regimen for patients undergoing left-sided ablation procedures
Document Type
article
Source
Indian Pacing and Electrophysiology Journal, Vol 16, Iss 6, Pp 181-184 (2016)
Subject
Ablation
Arrhythmia
Heparin
Diseases of the circulatory (Cardiovascular) system
RC666-701
Language
English
ISSN
0972-6292
Abstract
Background: Current guidelines for anticoagulation during left-sided procedures recommend the administration of unfractionated heparin (UFH) with an initial bolus of 50–100 U/kg, followed by continuous infusion to maintain an activated clotting time (ACT) ≥ 300 s. Our objective was to compare the effectiveness of this standard regimen (100 U/kg bolus) to a more aggressive approach (200 U/kg bolus). Methods: We collected data on a series of consecutive patients undergoing left sided ablation procedures. Patients with an INR ≥2.0 on the day of the procedure were excluded. Procedural anticoagulation was performed using one of two UFH regimens: 1) 100 U/kg bolus, followed by 10 U/kg/hour infusion or 2) 200 U/kg bolus, followed by 20 U/kg/hour infusion. ACT was measured 10 min after the second bolus and then controlled every 20 min. Heparin was titrated throughout the procedure to maintain an ACT 300–400 s. Results: 145 consecutive patients were included in the study: 34 received an initial bolus of 100 U/kg and 111 received 200 U/kg. The mean time required to reach an ACT ≥300 s was 15.25 min (95% CI 12.97–17.03) in the 200 U/kg group and 51.23 min (95% CI 40.65–61.81) in the 100 U/kg group (p