[Refractive Results after Implantation of Toric Intraocular Lenses Using the Zeiss Callisto System].
Document Type
Academic Journal
Author
Raemy K; Medizinische Fakultät, Universität Zürich, Zürich, Schweiz.; Scherrer M; Augenklinik, Kantonsspital Winterthur, Winterthur, Schweiz.; Stürmer JPE; Augenklinik, Kantonsspital Winterthur, Winterthur, Schweiz.
Source
Publisher: Thieme Country of Publication: Germany NLM ID: 0014133 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1439-3999 (Electronic) Linking ISSN: 00232165 NLM ISO Abbreviation: Klin Monbl Augenheilkd Subsets: MEDLINE
Subject
Language
German
Abstract
Background: For cataract patients with astigmatism, the insertion of a toric intraocular lens is a safe and effective method to achieve emmetropia. The exact alignment of the lens along the calculated axis is essential for effective correction of astigmatism. The purpose of this study is to evaluate our own data using descriptive statistics. The primary focus is on the refractive outcome and thus the verification of the alignment accuracy of toric IOLs with the Zeiss Callisto system.
Patients and Methods: The study evaluated a total of 106 eyes of 72 patients who underwent cataract surgery with implantation of a toric intraocular lens at our hospital between January 2019 and December 2020. Preoperative biometry and intraoperative marking of the implantation axis was performed using the Zeiss Callisto system. Postoperative controls were performed after one day, one week and 4 weeks, either at our hospital or by the referring ophthalmologist. For the analysis, only the data of the 4-week control were used.
Results: In 64 eyes (60%), a Zeiss AT Torbi 709 M or MP and in 42 eyes (40%) a PhysIOL Ankoris toric yellow IOL were implanted. In 46 eyes, postoperative uncorrected visual acuity was not recorded. Of the remaining 60 eyes, the mean postoperative uncorrected visual acuity was 0.07 ± 0.12 logMAR. Postoperative uncorrected visual acuity ≥ 1.0 (decimal) was achieved in 48% of the eyes and visual acuity ≥ 0.6 (decimal) in 92%. The postoperative cylinder averaged - 0.65 ± 0.53 D. The cylinder of the target refraction was - 0.45 ± 0.39 D on average. The mean of the absolute value of the postoperative cylinder minus the cylinder of the target refraction was 0.42 ± 0.32 D.
Conclusions: The Zeiss Callisto system is an effective tool to align toric intraocular lenses.
Competing Interests: Die Autorinnen/Autoren geben an, dass kein Interessenkonflikt besteht.